Описание

Function Input module with isolated inputs
Application emergency stop +
Application light barrier +
Cat. / PL according to EN ISO 13849-1 2/d
Width 45 mm
Type BH 5914.08/_0___
According to- Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061- Safety Integrity Level (SIL 2) to IEC/EN 61508 Input module for realization of:- 8 E-STOP, single-channel, autostart- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart- 5 E-STOP, single-channel, + 1 -STOP, 2-channel + 1 signal inut,autostart- 8 E-STOP, single-channel, manual start- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, manual start- 5 E-STOP, single-channel, + 1 E-STOP, 2-channel +1 signal input, manual start- As an alternative to the 2-channel E-STOP, a light curtain(LC type 4) according to EN 61496-1 can be connected. Broken wire and short circuit monitoring function with error indication 2 semiconductor outputs per function module for status indication LEDs for status indication Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)''