Описание

Function Emergency stop module with delay up to 600s / Safety gate monitor
Cat. / PL according to EN ISO 13849-1 3/d
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1, 2
Output contacts max. 3 s, 1 o, 1 sv
Thermal current Ith max. 10 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC +
Removable terminals +
Width 100 mm
Type BO 5988.47
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V 1-channel or 2-channel connection Line fault detection at On pushbutton Feedback circuit X1-X2 for monitoring external contactors Integrated short-circuit and overvoltage protection LED displays for channels 1 and 2 and supply Removable terminal strips Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),DIN 46 228-1/-2/-3-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 Optionally with release delayed NO contact to 10 min Optionally automatic On function after connection of operating voltageor activation via On pushbutton Optionally cross fault detection in emergency stop control circuit Optionally dual voltage version Width 100 mm''